Published July 1977 | Version v1
Journal article

Radon and thoron working levels from ordinary industrial-hygiene dust samples

Creators

  • 1. Institute of Occupational Medicine, Edinburgh (UK)

Description

The method is an improvement of that of Ogden (Ogden, T.L., Ann. Occup. Hyg., 17, 1974, 23-34), and has the following advantages over other methods: the measurements do not require special samples, but can be made on ordinary airborne dust samples; the long sampling time (> 2 1/2 h) is more suitable for estimating average exposure than the conventional short sample; radon and thoron working levels are both obtained; and the method is very sensitive (0.001 WL is easily measured). Side by side comparisions show good agreement with other methods. (author)

Additional details

Identifiers

Publishing Information

Journal Title
The Annals of Occupational Hygiene
Journal Volume
20
Journal Issue
1
Series
Ann. Occup. Hyg.
Journal Page Range
49-53
ISSN
0003-4878

Optional Information

Notes
Updated automatically by Metadata and Full-Text Enrichment Agent