Published June 2008 | Version v1
Journal article

BeO preparation and AMS measurement result for loess samples

  • 1. Xi'an AMS Center, Xi'an (China)
  • 2. Chinese Academy of Sciences, Xi'an (China). Inst. of Earth Environment, State Key Lab of Loess and Quaternary Geology
  • 3. Xi'an Jiaotong Univ., Xi'an (China)
  • 4. Chinese Academy of Sciences, Beijing (China). Graduate Univ.

Description

The classic procedure of BeO preparation for loess-paleosol cannot restrain the concentration of 10B effectively, which results in higher background of 10Be measurement. the procedure has been modified in this paper. It includes detailed eluting curve for cation exchanging, the method of converting Be(OH)2 to BeO, and the experiment equipments. the measurement results by Xi'an AMS indicate that the background of modified BeO preparation procedure can be lowered to 2.04 x 10-14 on 3 MV AMS. The method and measurement results have also been introduced for Xi'an-AMS. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Techniques
Journal Volume
31
Journal Issue
6
Journal Page Range
p. 427-432
ISSN
0253-3219

Optional Information

Notes
3 figs., 5 tabs., 25 refs.