Published March 2010 | Version v1
Journal article

Pressure drops in gas-liquid two-phase flow in a rod bundle with partial length rods

  • 1. Kobe Univ., Graduate School of Engineering, Kobe, Hyogo (Japan)

Description

Pressure drops in air-water two-phase flows in a four by four rod bundle with partial length rods (PLR) are measured by using differential pressure transducers. The sampling frequency is 0.2 kHz and sampling number is 50000. The experimental apparatus consists of an acrylic channel box and 16 stainless rods. Air and water at atmospheric pressure and room temperature are used for the gas and liquid phases, respectively. The ranges of the gas and liquid volume fluxes, JG and JL, are 0.4 < JL < 2.0 m/s and 0.06 < JG < 8.85 m/s, which cover typical two-phase flow patterns appearing in the fuel bundle. As a result, the following conclusions are obtained: (1) Although the pressure drop decreases with increasing the number of PLRs, the magnitude of the pressure reduction scarcely depends on their locations. (2) The pressure drop is well evaluated by using the void correlation proposed by Ishizuka et al. and the homogeneous model for the frictional pressure drop. (author)

Availability note (English)

Available from http://dx.doi.org/10.3811/jjmf.23.547

Additional details

Identifiers

Publishing Information

Journal Title
Konsoryu
Journal Volume
23
Journal Issue
5
Journal Page Range
p. 547-554
ISSN
0914-2843

Optional Information

Notes
17 refs., 11 figs., 2 tabs.