Published November 1995 | Version v1
Report Open

Flow-induced vibration specifications for steam generators and liquid heat exchangers

  • 1. Atomic Energy of Canada Ltd., Chalk River, ON (Canada). Chalk River Nuclear Labs.
  • 2. Ontario Hydro, Toronto, ON (Canada)

Description

It is desirable to avoid vibration problems by following appropriate guidelines and specifications at the design stage. Accordingly, design specifications were developed to prevent tube failures due to vibration in nuclear steam generators and liquid heat exchangers. These specifications are outlined in this report. (author). 14 refs., 2 figs

Availability note (English)

MF available from INIS under the Report Number.

Files

27051524.pdf

Files (534.0 kB)

Name Size Download all
md5:f835d191ca40564050aa80c910ee820f
534.0 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
27 p.
Report number
AECL--11401

Optional Information

Secondary number(s)
COG--95-341-I.