Published November 1995
| Version v1
Report
Open
Flow-induced vibration specifications for steam generators and liquid heat exchangers
Creators
- 1. Atomic Energy of Canada Ltd., Chalk River, ON (Canada). Chalk River Nuclear Labs.
- 2. Ontario Hydro, Toronto, ON (Canada)
Description
It is desirable to avoid vibration problems by following appropriate guidelines and specifications at the design stage. Accordingly, design specifications were developed to prevent tube failures due to vibration in nuclear steam generators and liquid heat exchangers. These specifications are outlined in this report. (author). 14 refs., 2 figs
Availability note (English)
MF available from INIS under the Report Number.Files
27051524.pdf
Files
(534.0 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:f835d191ca40564050aa80c910ee820f
|
534.0 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 27 p.
- Report number
- AECL--11401
INIS
- Country of Publication
- Canada
- Country of Input or Organization
- Canada
- INIS RN
- 27051524
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Descriptors DEI
- FLOW RATE; FLUID FLOW; FLUID MECHANICS; FRETTING CORROSION; HEAT EXCHANGERS; MECHANICAL VIBRATIONS; RESONANCE; SPECIFICATIONS; STEAM GENERATORS; TWO-PHASE FLOW
- Descriptors DEC
- BOILERS; CHEMICAL REACTIONS; CORROSION; MECHANICS; VAPOR GENERATORS
Optional Information
- Secondary number(s)
- COG--95-341-I.