Prospective multicenter study on personalized and optimized MDCT contrast protocols. Results on liver enhancement
- 1. Palindromo Consulting, Willem de Corylaan, 51 3001, Leuven (Belgium)
- 2. Institut de Radiologie de Sion, Groupe 3R, Sion (Switzerland)
- 3. GE Healthcare, Buc (France)
- 4. Institute of Radiation Physics (IRA), Lausanne University Hospital and University of Lausanne, Lausanne (Switzerland)
- 5. Centre d'Imagerie de Fribourg, Groupe 3R, Fribourg (Switzerland)
Description
To determine a personalized and optimized contrast injection protocol for a uniform and optimal diagnostic level of liver parenchymal enhancement, in a large patient population enrolled in a multicenter study. Six hundred ninety-two patients who underwent a standardized multi-phase liver CT examination were prospectively assigned to one contrast media (CM) protocol group: G1 (100 mL fixed volume, 37 gI); G2 (600 mgI/kg of total body weight (TBW)); G3 (750 mgI/kg of fat-free mass (FFM)), and G4 (600 mgI/kg of FFM). Change in liver parenchyma CT number between unenhanced and contrast-enhanced images was measured by two radiologists, on 3-mm pre-contrast and portal phase axial reconstructions. The enhancement histograms were compared across CM protocols, specifically according to a target diagnostic value of 50 HU. The total amount of iodine dose was also compared among protocols by median and interquartile range (IQR). The Kruskal-Wallis and Mann-Whitney U tests were used to assess significant differences (p < 0.005), as appropriate. A significant difference (p < 0.001) was found across the groups with liver enhancement decreasing from median over-enhanced values of 77.0 (G1), 71.3 (G2), and 65.1 (G3) to a target enhancement of 53.2 HU for G4. Enhancement IQR was progressively reduced from 26.5 HU (G1), 26.0 HU (G2), and 17.8 HU (G3) to 14.5 HU (G4). G4 showed a median iodine dose of 26.0 gI, significantly lower (p < 0.001) than G3 (33.9 gI), G2 (38.8 gI), and G1 (37 gI). The 600 mgI/kg FFM-based protocol enabled a diagnostically optimized liver enhancement and improved patient-to-patient enhancement uniformity, while significantly reducing iodine load.
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-021-07953-3Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology (Internet)
- Journal Volume
- 31
- Journal Issue
- 11
- Journal Page Range
- p. 8236-8245
- ISSN
- 1432-1084
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 53012595
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ABDOMEN; BODY COMPOSITION; COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; CONTRAST MEDIA; DATA COMPILATION; DOSES; INTRAVENOUS INJECTION; IODINE; LIVER; OPTIMIZATION; WEIGHT
- Descriptors DEC
- BODY; DATA; DATA PROCESSING; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; ELEMENTS; EVALUATION; GLANDS; HALOGENS; INFORMATION; INJECTION; INTAKE; NONMETALS; ORGANS; PROCESSING; TOMOGRAPHY