A new model for surface potential decay of corona-charged polymers
Creators
- 1. School of Electronics and Computer Science, University Of Southampton, Southampton, SO16 1BJ (United Kingdom)
Description
Surface potential measurement provides a useful tool to gauge the electrical properties of materials. It has been observed that the potential of a sample with an initial high surface potential decays faster than that with an initial lower surface potential, known as the cross-over phenomenon. The phenomenon was found a few decades ago and various theories and models have been proposed. A common feature of the existing models is based on single charge carrier injection from a corona-charged surface. With our recent space charge measurement results on corona-charged samples, double injection from both electrodes has been verified. Based on this new fact, a new model based on bipolar charge injection is proposed and initial numerical simulation reveals that the surface potential cross-over phenomenon can occur under bipolar charge injection.
Availability note (English)
Available from http://dx.doi.org/10.1088/0022-3727/43/5/055405Additional details
Identifiers
- DOI
- 10.1088/0022-3727/43/5/055405;
- PII
- S0022-3727(10)30984-3;
Publishing Information
- Journal Title
- Journal of Physics. D, Applied Physics
- Journal Volume
- 43
- Journal Issue
- 5
- Journal Page Range
- [7 p.]
- ISSN
- 0022-3727
- CODEN
- JPAPBE
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 42059474
- Subject category
- S43: PARTICLE ACCELERATORS; S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
- Descriptors DEI
- CHARGE CARRIERS; COMPUTERIZED SIMULATION; ELECTRICAL PROPERTIES; ELECTRODES; POLYMERS; SPACE CHARGE; SURFACE POTENTIAL
- Descriptors DEC
- PHYSICAL PROPERTIES; POTENTIALS; SIMULATION