Published 1994 | Version v1
Report Open

Flow reversal and thermal limit in a heated rectangular channel

  • 1. Brookhaven National Lab., Upton, NY (United States)
  • 2. Columbia Univ., New York, NY (United States)
  • 3. Villanova Univ., PA (United States)

Description

The thermal limit in a vertical rectangular channel was determined in a series of experiments whereby the internal coolant underwent a change in flow direction from forced downflow to upward natural circulation. The tests were designed to simulate the flow reversal transient in the High Flux Beam Reactor. A number of parameters were varied in the flow reversal experiments to examine their effects on the thermal limit. Among the parameters varied were the rate of flow coastdown, inlet subcooling, water level in the upper plenum, bypass ratio (ratio of initial flow through the heated section to initial flow through the bypass orifice), and single- verses double-sided heating

Availability note (English)

MF available from INIS under the Report Number; Also available from OSTI as DE94014875; NTIS; US Govt. Printing Office Dep.

Files

26017048.pdf

Files (932.2 kB)

Name Size Download all
md5:a7e10163d5b9dc24250744a421824d3f
932.2 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
8 p.
Report number
BNL--60600

Conference

Title
American Society of Mechanical Engineers' winter annual meeting.
Dates
9-11 Nov 1994.
Place
Chicago, IL (United States).

Optional Information

Contract/Grant/Project number
Contract AC02-76CH00016
Funding organization
USDOE, Washington, DC (United States).
Secondary number(s)
CONF-941142--12.