Determination of attenuation factors for mortar of barite in terms of environmental dose equivalent and effective dose
Creators
- Almeida Junior, Airton T.1
- Campos, L.L.R.1
- Araujo, F.G.S.2
- Santos, M.A.P.3
- Nogueira, M.S.4
- Sociedade Brasileira de Protecao Radiologica (SBPR), Recife, PB (Brazil)
- Associacao Brasileira de Ensaios nao Destrutivos e Inspecao (ABENDI), Sao Paulo, SP (Brazil)
- Federacion de Radioproteccion da America Latina y el Caribe (FRALC), Rio de Janeiro, RJ (Brazil)
- 1. Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)
- 2. Universidade Federal de Ouro Preto (UFOP), Ouro Preto, MG (Brazil)
- 3. Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)
- 4. Centro de Desenvolvimeto da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)
Description
This work addresses the characterization of barite mortars used as Xray shielding materials through the following quantities: mass attenuation coefficient, air kerma, effective dose and ambient dose - H⁎(10). The experiment was carried out with the use of the following reference qualities: RQR4, RQR6, RQR9 e RQR10, specified in accordance with norm IEC 61267: Medical diagnostic Xray equipment - radiation conditions for use in the determination of characteristics. In this study values was determined experimentally for the attenuation of the Cream barite (density 2.99g/cm3, collected in the state of Sao Paulo), Purple barite (density 2.95g/cm3, collected in the state of Bahia) and White barite (density 3.10g/cm3, collected in the state of Paraiba). These materials, in the form of mortar, were disposed in the form of squares namely poof bodies, whose dimensions were 10 x 10 cm and thickness ranging from 3 to 15 mm approximately. In the experimental procedure, these proof bodies were irradiated with a Pantak, model HF320 industrial X-ray apparatus. The potentials applied to the respective X-ray tube were: 60kV, 80kV, 120kV and 150kV at a constant current of 1mA. The attenuation responses in function of thickness, for each of the materials analyzed, were used to draw the attenuation and transmission curves. The efficiency of the barite studied concerning the capacity to attenuate X-ray radiation for X-ray beams ranging from 60 to 150 kV indicated
Files
46034427.pdf
Files
(721.3 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:8c3c1fbf6af7190e8f8087fad853c465
|
721.3 kB | Preview Download |
Additional details
Additional titles
- Original title (Portuguese)
- Determinacao de fatores de atenuacao para argamassa de barita em termos do equivalente de dose ambiental e dose efetiva
Publishing Information
- Imprint Pagination
- 14 p.
- Report number
- INIS-BR--14951
Conference
- Title
- International joint conference Radio 2014
- Dates
- 26-29 Aug 2014
- Place
- Gramado, RS (Brazil)
INIS
- Country of Publication
- Brazil
- Country of Input or Organization
- Brazil
- INIS RN
- 46034427
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S36: MATERIALS SCIENCE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ATTENUATION; BARITE; BRAZILIAN CNEN; ENVIRONMENTAL EXPOSURE; EQUIPMENT; KERMA; MATERIALS; MORTARS; RADIATION DOSES; RADIATION PROTECTION; SHIELDING; X RADIATION
- Descriptors DEC
- BRAZILIAN ORGANIZATIONS; DOSES; ELECTROMAGNETIC RADIATION; IONIZING RADIATIONS; MINERALS; NATIONAL ORGANIZATIONS; RADIATIONS; SULFATE MINERALS