Large-volume multi-tined expandable RF ablation in pig livers: comparison of 2D and volumetric measurements of the ablation zone

  • 1. University of Cologne, Department of Radiology, Cologne (Germany)
  • 2. University of Cologne, Department of Visceral and Vascular Surgery, Cologne (Germany)
  • 3. Philips Forschungslaboratorien, Hamburg (Germany)
  • 4. University of Cologne, Institute of Medical Statistics, Informatics and Epidemiology, Cologne (Germany)
  • 5. University of Cologne, Institute of Experimental Medicine, Cologne (Germany)

Description

To compare two-dimensional (2D) and three-dimensional (3D) computed tomography (CT) measurements of ablation zones (AZs) related to the shaft of two different large-volume monopolar multi-tined expandable electrodes. Percutaneous radiofrequency (RF) ablation was performed in 12 pigs (81.6±7.8 kg) using two electrodes (LeVeen 5 cm, Rita XL 5 cm; n=6 in each group). Contrast-enhanced CT with the electrode shaft in place evaluated the AZ. The largest sphere centred on the electrode shaft within the AZ was calculated (1) based on the 2D axial CT image in the plane of the shaft assuming rotational symmetry of the AZ and (2) using prototype software and the 3D volume data of the AZ measured with CT. The mean largest diameter of a sphere centred on the electrode shaft was always smaller using the 3D data of the AZ than using 2D CT measurements assuming rotational symmetry of the AZ (3D vs 2D): LeVeen 18.2±4.8 mm; 24.5 ±3.1 mm; p=0.001; Rita XL 20.0±3.7 mm; 28.8±4.9 mm; p=0.0002. All AZ showed indentations around the tines. Two-dimensional CT measurements assuming rotational symmetry of the AZ overestimate the largest ablated sphere centred on the electrode shaft compared with 3D CT measurements. (orig.)

Availability note (English)

Available from: http://dx.doi.org/10.1007/s00330-009-1639-4

Additional details

Identifiers

Publishing Information

Journal Title
European Radiology
Journal Volume
20
Journal Issue
5
Journal Page Range
p. 1073-1078
ISSN
0938-7994
CODEN
EURAE3

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
41057752
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Numerical Data
Descriptors DEI
COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; EXPERIMENTAL DATA; LIVER; SWINE
Descriptors DEC
ANIMALS; BODY; DATA; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; DOMESTIC ANIMALS; EVALUATION; GLANDS; INFORMATION; MAMMALS; NUMERICAL DATA; ORGANS; TOMOGRAPHY; VERTEBRATES