Intraosseous rotation of the scaphoid: assessment by using a 3D CT model - an anatomic study
Creators
- 1. Medical University Innsbruck, Department of Trauma Surgery, Innsbruck (Austria)
- 2. Regional Hospital Hall, Department of Radiology, Hall in Tirol (Austria)
- 3. Medical University Innsbruck, Department of Radiology, Innsbruck (Austria)
- 4. Medical University Innsbruck, Department of Anatomy, Histology and Embryology-Division of Clinical and Functional Anatomy, Innsbruck (Austria)
Description
The purpose of this study was to assess intraosseous rotation as the third dimension of scaphoid anatomy on a 3D CT model using common volume rendering software to impact anatomical reconstruction of scaphoid fractures. CT images of 13 cadaver wrist pairs were acquired. Reference axes for the alignment of distal and proximal scaphoid poles were defined three-dimensionally. Two methods for rotation measurement - the reference axis method (RAM) and the scapho-trapezio-trapezoidal joint method (STTM) - were developed and compared by three independent observers. Rotation measured by the RAM averaged 66.9 ± 7 for the right and 67.2 ± 5.8 for the left wrists. Using the STTM there was a mean rotation of 68.6 ± 6.6 for the right and 68.6 ± 6.8 for the left wrists. The overall results showed a significant variability of the measured values between different specimens (P < 0.05). There was no significant difference between left and right wrists of the same specimen, neither for the RAM (P = 0.268) nor for the STTM (P = 0.774). Repeatability coefficients between the observers were low, indicating good repeatability. The presented methods are practical tools to quantify intraosseous rotation between distal and proximal scaphoid poles using common volume rendering software. For clinical application the opposite side provides the best reference values to assess malrotation in scaphoid fracture cases. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-014-3116-yAdditional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 24
- Journal Issue
- 6
- Journal Page Range
- p. 1357-1365
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 45081720
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ALIGNMENT; ANATOMY; BONE FRACTURES; CLINICAL TRIALS; COMPUTERIZED TOMOGRAPHY; HANDS; IMAGE PROCESSING; PATHOLOGY; ROTATION; THREE-DIMENSIONAL CALCULATIONS
- Descriptors DEC
- ARMS; BIOLOGY; BODY; DIAGNOSTIC TECHNIQUES; DISEASES; INJURIES; LIMBS; MOTION; PROCESSING; TESTING; TOMOGRAPHY