Usability evaluation through gonad shielding production of pediatric patients by gender and age rating
Creators
- 1. Dept. of Radiology, Kyung Hee University Hospital at Gangdong, Seoul (Korea, Republic of)
- 2. Dept. of Nuclear Engineering, Chosun University, Gwangju (Korea, Republic of)
- 3. Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of)
Description
The gonad shielding is used to minimize the impact of the exposure to gonads when Abdomen, Plevis and Hip X-ray inspections are conducted on radiation impressionable pediatric patients. By the way, the gonad is palpable difficult and impossible to check visually because it's a sensitive area, so tests are conducted with the approximate location of shielding, thereby appearing problems of not shielding gonads accurately. Accordingly, this study produced shields by age and gender of pediatric patients and studied the method of positioning shields with ASIS as a reference point without palpable sensitive areas, and tried to evaluate its usability. The study surveyed 30 pediatric patients by gender and age, who came and got inspected in Department of Radiology, our hospital from February 2012 to January 2014 and obtained the value of tolerance by measuring the average size of the pelvis using the distance measurement function of Infinitt Piview with the images stored in the PACS and producing shields by age and gender of pediatric patients and specifying the areas at random for the comparative analysis of pre- and post-using. It calculated the technology statistics (mean±SD) with the value of tolerance measured the length using SPSS 12.0 statistical program. As for boys, differences in the tolerance range of pre- and post-using shields were 2.69 mm in case of 1 year old, 2.58 mm in 2 years, 2.37 mm in 3 years, 2.815 mm in 4-5 years, 2.043 mm in 7-10 years, and as for girls,1.92 mm in 1-2 years, 1.75 mm in 3-4 years, 2.52 mm in 5-6 years and 1.93 mm in 7-10. After analyzing the pre- and post-using shields for all of boys and girls, there were statistically significant differences (P<0.050). It is considered that we can minimize the exposure to gonads and get a better video for diagnosis in testing high biological impressionable pediatric, if we use shields correctly with ASIS as a reference point considering its shape and size by age and gender in Abdomen, Plevis and Hip X-ray inspections
Additional details
Publishing Information
- Journal Title
- Journal of Radiation Industry
- Journal Volume
- 9
- Journal Issue
- 2
- Series
- 8 refs, 5 figs, 4 tabs
- Journal Page Range
- p. 69-75
- ISSN
- 1976-2402
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 47084812
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ABDOMEN; ACCURACY; DIAGNOSIS; LEGS; PATIENTS; PEDIATRICS; PELVIS; RADIATION PROTECTION; SHIELDING
- Descriptors DEC
- BODY; LIMBS; MEDICINE