Prototype mitre bends of the ex-vessel waveguide system for the ITER upper launcher: Thermal hydraulic simulations and experiments with off-center mm-wave beams
- 1. Ecole Polytechnique Fédérale de Lausanne (EPFL), Swiss Plasma Center (SPC), CH-1015 Lausanne (Switzerland)
- 2. Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, E-08019 Barcelona (Spain)
Description
On ITER, long pulse gyrotrons are required as a power source for electron cyclotron heating (ECH) and current drive (CD). The microwaves are guided from the gyrotrons, which are placed far from the Tokamak, into the plasma by transmission lines (TLs) and a launching antenna (launcher). Each of the four ECH Upper launchers features eight waveguide (WG) TLs, with at least 95% of the power from the gyrotrons coupled into in the main HE mode of the TLs. In the ex-vessel portion of the system between the port-plug closure plate and the isolation valve and diamond window, there are miter bends (MBs) that change the direction of the TL by reflecting the millimeter waves (mm-waves) using mirrors; the mirrors must handle 1.31 MW, 170 GHz, 3600 s pulses. Various MBs perform these reflections at an angle of 90 degrees, or nearly 100 degrees. As a result of the ohmic dissipation, an intensive peaked heat flux appears near the center of the MB mirror and thus, a dedicated cooling system is present to ensure the temperature control of the mirror and housing e.g. [1]. The power that is not found in the HE mode can cause the beam to be not perfectly centered, resulting in an off-centered heat flux on the mirror surface; as is the case for the experiments described here. This study presents new finite element modeling of such beams, created in CFX of ANSYS Workbench [2], compared to the experimental findings for pulses of 170 GHz, 0.5 MW and 240 s. Monitor points are placed in the same positions as TCs that have been fitted in the mirror close to the heated surface and direct comparison of the temperature values is performed. Through transient simulation the time constants are calculated and compared with those of the experiments.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.fusengdes.2021.112457Additional details
Identifiers
- DOI
- 10.1016/j.fusengdes.2021.112457;
- PII
- S0920379621002337;
Publishing Information
- Journal Title
- Fusion Engineering and Design
- Journal Volume
- 170
- Journal Page Range
- vp.
- ISSN
- 0920-3796
- CODEN
- FEDEEE
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 54093933
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY; S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
- Descriptors DEI
- ANTENNAS; COMPUTERIZED SIMULATION; COOLING SYSTEMS; ECR HEATING; FINITE ELEMENT METHOD; GHZ RANGE; HEAT FLUX; ITER TOKAMAK; MICROWAVE AMPLIFIERS; MICROWAVE RADIATION; MIRRORS; PLASMA; PLATES; PULSES; THERMAL HYDRAULICS; VALVES; WAVEGUIDES
- Descriptors DEC
- AMPLIFIERS; CALCULATION METHODS; CLOSED PLASMA DEVICES; CONTROL EQUIPMENT; ELECTRICAL EQUIPMENT; ELECTROMAGNETIC RADIATION; ELECTRONIC EQUIPMENT; ENERGY SYSTEMS; EQUIPMENT; FLOW REGULATORS; FLUID MECHANICS; FREQUENCY RANGE; HEATING; HIGH-FREQUENCY HEATING; HYDRAULICS; MATHEMATICAL SOLUTIONS; MECHANICS; MICROWAVE EQUIPMENT; NUMERICAL SOLUTION; PLASMA HEATING; RADIATIONS; SIMULATION; THERMONUCLEAR DEVICES; THERMONUCLEAR REACTORS; TOKAMAK DEVICES; TOKAMAK TYPE REACTORS