Published September 2010 | Version v1
Journal article

Finite element analysis of hip resurfacing arthroplasty with different implant angles

  • 1. Department of Radiology, Tianjin First Hospital (China)

Description

Objective: To explore the biomechanical influences of femoral prosthesis implantation angle in 3-dimensional finite element (3D FE) models of Hip Resurfacing Arthroplasty (HRSA). Methods: Five different implant angles of HRSA 3D FE models were constructed based on the human anatomical data from multislice spiral CT. The femoral prosthesis implantation angle was 120°, 125°, 130°, 135°, 140°, and 145° respectively. Pressure was added on each model to simulate status in normal walking. The patterns of the stress distribution on each model were analyzed. Results: The stress concentration presented at head-neck junction part of the resurfaced femur. The maximum Von Mises stress value was decreased while increasing the femoral implant angles. However, the change was not obviously when the angle range from 135° to 145°. Conclusion: The optimal angle of femoral prosthesis implantation in HRSA is from 135° to 145°. (authors)

Additional details

Publishing Information

Journal Title
International Journal of Medical Radiology
Journal Volume
33
Journal Issue
5
Journal Page Range
p. 451-455
ISSN
1674-1897

Optional Information

Notes
12 figs., 2 tabs., 20 refs.