Published July 1975
| Version v1
Report
Restricted
Incore power distribution determination in Westinghouse pressurized water reactors
Description
Determination of power distribution using the In-Core Instrumentation System is periodically performed in the Westinghouse Pressurized Water Reactor. The measurements taken are then normally compiled into useful information for the plant operation using digital computation techniques. The instrumentation system employed to take these measurements and INCORE code which is used to process the information obtained are described. (U.S.)
Availability note (English)
MF available from INIS under the Report Number.
Files
Additional details
Publishing Information
- Imprint Pagination
- 36 p.
- Report number
- WCAP--8498
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 7225523
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- DATA PROCESSING; I CODES; MEASURING METHODS; POWER DENSITY; PWR TYPE REACTORS; REACTOR INSTRUMENTATION
- Descriptors DEC
- COMPUTER CODES; REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- Westinghouse Electric Corp., Pittsburgh.