Published January 2007 | Version v1
Journal article

Research and measurement of BPM system at HLS LINAC

  • 1. National Synchrotron Radiation Laboratory, Univ. of Science and Technology of China, Hefei (China)

Description

BPM system newly designed at HLS Linac has been installed and applied in beam based experiments. This paper introduces the structure of BPM system, signal processing module, mapping results and measurement results of beam based experiment. The BPM system has a dynamic range of not less than 40 dBm, beam position resolution of less than 100 μm, horizontal sensitivity of 1.61 dB/mm and vertical sensitivity of 1.51 dB/mm. The results of experiment between corrector strength and BPM shows that the newly designed BPM system can acquire the beam positions information correctly, and the horizontal and vertical correction coefficients of the correctors are 0.46 mm/A and 0.58 mm/A respectively, and the horizontal and vertical beam positions at BPM are 0.83 mm and -0.57 mm respectively with the default value of correctors. (authors)

Additional details

Publishing Information

Journal Title
High Energy Physics and Nuclear Physics
Journal Volume
31
Journal Issue
1
Journal Page Range
p. 96-100
ISSN
0254-3052

Optional Information

Notes
10 figs., 6 refs.