An Evaluation of Bipolar Junction Transistors as Dosimeter for Megavoltage Electron Beams
Creators
- 1. Departamento de Fisica, Universidade Federal de Sergipe, Av. Marechal Rondon, sn, Sao Cristovao, SE, 49100-000 (Brazil)
- 2. Comissao Nacional de Energia Nuclear, CNEN/CRCN-NE, Av. Prof. Luiz Freire, 1, Recife, PE, 50740-540 (Brazil)
Description
Dosimetry is an extremely important field in medical applications of radiation and nowadays, electron beam is a good option for superficial tumor radiotherapy. Normally, the applied dose to the patient both in diagnostic and therapy must be monitored to prevent injuries and ensure the success of the treatment, therefore, we should always look for improving of the dosimetric methods. Accordingly, the aim of this work is about the use of a bipolar junction transistor (BJT) for electron beam dosimetry. After previous studies, such an electronic device can work as a dosimeter when submitted to ionizing radiation of photon beam. Actually, a typical BJT consists of two PN semiconductor junctions resulting in the NPN structure device, for while, and each semiconductor is named as collector (C), base (B) and emitter (E), respectively. Although the transistor effect, which corresponds to the current amplification, be accurately described by the quantum physics, one can utilize a simple concept from the circuit theory: the base current IB (input signal) is amplified by a factor of β resulting in the collector current IC (output signal) at least one hundred times greater the IB. In fact, the BJT is commonly used as a current amplifier with gain β=IC/IB, therefore, it was noticed that this parameter is altered when the device is exposed to ionizing radiation. The current gain alteration can be explained by the trap creation and the positive charges build up, beside the degradation of the lattice structure. Then, variations of the gain of irradiated transistors may justify their use as a dosimeter. Actually, the methodology is based on the measurements of the IC variations whereas IB is maintained constant. BC846 BJT type was used for dose monitoring from passive-mode measurements: evaluation of its electrical characteristic before and after irradiation procedure. Thus, IC readings were plotted as a function of the applied dose in 6 MeV electron beam from a linear accelerator, Clinac iX. The results show that this new methodology could be an alternative to study the dose in superficial tumors in radiation oncology. (authors)
Additional details
Publishing Information
- Imprint Pagination
- 1 p.
- Report number
- ANIMMA--2015-IO-330
Conference
- Title
- 4. International Conference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications
- Acronym
- ANIMMA 2015
- Dates
- 20-24 Apr 2015
- Place
- Lisboa (Portugal)
INIS
- Country of Publication
- United States
- Country of Input or Organization
- France
- INIS RN
- 47102319
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- AMPLIFIERS; CIRCUIT THEORY; DOSEMETERS; DOSIMETRY; ELECTRON BEAMS; GAIN; INJURIES; IRRADIATION PROCEDURES; JUNCTION TRANSISTORS; LINEAR ACCELERATORS; MEV RANGE; MONITORING; NEOPLASMS; PATIENTS; PHOTON BEAMS; QUANTUM MECHANICS; RADIOTHERAPY; SEMICONDUCTOR JUNCTIONS; SEMICONDUCTOR MATERIALS; TRAPS
- Descriptors DEC
- ACCELERATORS; AMPLIFICATION; BEAMS; DISEASES; ELECTRONIC EQUIPMENT; ENERGY RANGE; EQUIPMENT; LEPTON BEAMS; MATERIALS; MEASURING INSTRUMENTS; MECHANICS; MEDICINE; NUCLEAR MEDICINE; PARTICLE BEAMS; RADIOLOGY; SEMICONDUCTOR DEVICES; THERAPY; TRANSISTORS