Published October 1, 1981 | Version v1
Journal article

2nd--5th electron cyclotron harmonic emission from thermal plasmas in Alcator A

  • 1. Plasma fusion center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139

Description

A sensitive submillimeter heterodyne receiver has been used to measure electron cyclotron emission at the 2nd through the 5th harmonics from thermal plasmas in Alcator A. A sensitive diagnostic of the electron energy distribution function is obtained from intensity ratios of the optically thin harmonics, in particular the small runaway fraction (approx.10-6) that exists even in well thermalized Alcator A plasmas. Also the 4th and 5th harmonics are a sensitive measure of impending plasma disruption due to vessel air leaks

Additional details

Publishing Information

Journal Title
Appl. Phys. Lett.
Journal Volume
39
Journal Issue
7
Series
Appl. Phys. Lett.
Journal Page Range
548-550
ISSN