Published October 1, 1981
| Version v1
Journal article
2nd--5th electron cyclotron harmonic emission from thermal plasmas in Alcator A
- 1. Plasma fusion center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139
Description
A sensitive submillimeter heterodyne receiver has been used to measure electron cyclotron emission at the 2nd through the 5th harmonics from thermal plasmas in Alcator A. A sensitive diagnostic of the electron energy distribution function is obtained from intensity ratios of the optically thin harmonics, in particular the small runaway fraction (approx.10-6) that exists even in well thermalized Alcator A plasmas. Also the 4th and 5th harmonics are a sensitive measure of impending plasma disruption due to vessel air leaks
Additional details
Publishing Information
- Journal Title
- Appl. Phys. Lett.
- Journal Volume
- 39
- Journal Issue
- 7
- Series
- Appl. Phys. Lett.
- Journal Page Range
- 548-550
- ISSN
- 0003-6951
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 13646265
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- AIR; ALCATOR DEVICE; CYCLOTRON HARMONICS; DISTRIBUTION FUNCTIONS; ELECTRON CYCLOTRON-RESONANCE; ENERGY SPECTRA; HETERODYNE RECEIVERS; LEAKS; PLASMA; PLASMA DIAGNOSTICS; SENSITIVITY
- Descriptors DEC
- CLOSED PLASMA DEVICES; CYCLOTRON RESONANCE; ELECTRONIC EQUIPMENT; FLUIDS; GASES; HARMONICS; MICROWAVE EQUIPMENT; OSCILLATIONS; RADIO EQUIPMENT; RESONANCE; SPECTRA; THERMONUCLEAR DEVICES; TOKAMAK DEVICES