A Study of Improving Response Time Verification Method for Pressure Transmitters
- 1. Korea Power Engineering Company, Inc., Daejeon (Korea, Republic of)
Description
Technical Specifications (TS) of OPR1000 type nuclear power plants in Korea require pressure sensor response time testing (RTT) to ensure sensor performance per assumption in plant safety analyses. However, the need for pressure sensor response time testing is not clear because the nominal sensor response times are in the order of milliseconds while overall loop response time limits being from several seconds to tens of seconds. Additionally, response time testing does not appear to identify response time degradation or failures. Consequently, the need for this testing has been questioned, and a study to determine if response time testing is necessary to justify the assumptions in plant safety analyses in the United States has been conducted and NRC has approved to remove the test requirements for them. A similar study was conducted for OPR1000 type nuclear power plants and the results are presented here
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Daejeon (Korea, Republic of)
- Imprint Title
- Proceedings of the KNS autumn meeting
- Imprint Pagination
- [1 CD-ROM]
- Journal Page Range
- [2 p.]
Conference
- Title
- 2007 autumn meeting of the KNS
- Dates
- 25-26 Oct 2007
- Place
- Pyongchang (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 39078067
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- NUCLEAR POWER PLANTS; PERFORMANCE; PWR TYPE REACTORS; SAFETY ANALYSIS; SPECIFICATIONS; VERIFICATION
- Descriptors DEC
- ENRICHED URANIUM REACTORS; NUCLEAR FACILITIES; POWER PLANTS; POWER REACTORS; REACTORS; THERMAL POWER PLANTS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- 4 refs, 2 figs, 1 tab