Published October 2007 | Version v1
Miscellaneous

A Study of Improving Response Time Verification Method for Pressure Transmitters

  • 1. Korea Power Engineering Company, Inc., Daejeon (Korea, Republic of)

Description

Technical Specifications (TS) of OPR1000 type nuclear power plants in Korea require pressure sensor response time testing (RTT) to ensure sensor performance per assumption in plant safety analyses. However, the need for pressure sensor response time testing is not clear because the nominal sensor response times are in the order of milliseconds while overall loop response time limits being from several seconds to tens of seconds. Additionally, response time testing does not appear to identify response time degradation or failures. Consequently, the need for this testing has been questioned, and a study to determine if response time testing is necessary to justify the assumptions in plant safety analyses in the United States has been conducted and NRC has approved to remove the test requirements for them. A similar study was conducted for OPR1000 type nuclear power plants and the results are presented here

Part of:
Proceedings of the KNS autumn meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Daejeon (Korea, Republic of)
Imprint Title
Proceedings of the KNS autumn meeting
Imprint Pagination
[1 CD-ROM]
Journal Page Range
[2 p.]

Conference

Title
2007 autumn meeting of the KNS
Dates
25-26 Oct 2007
Place
Pyongchang (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
39078067
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
NUCLEAR POWER PLANTS; PERFORMANCE; PWR TYPE REACTORS; SAFETY ANALYSIS; SPECIFICATIONS; VERIFICATION
Descriptors DEC
ENRICHED URANIUM REACTORS; NUCLEAR FACILITIES; POWER PLANTS; POWER REACTORS; REACTORS; THERMAL POWER PLANTS; THERMAL REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS

Optional Information

Notes
4 refs, 2 figs, 1 tab