FFTF [Fast Flux Test Facility] reactor shutdown system reliability reevaluation
Description
The reliability analysis of the Fast Flux Test Facility reactor shutdown system was reevaluated. Failure information based on five years of plant operating experience was used to verify original reliability numbers or to establish new ones. Also, system modifications made subsequent to performance of the original analysis were incorporated into the reevaluation. Reliability calculations and sensitivity analyses were performed using a commercially available spreadsheet on a personal computer. The spreadsheet was configured so that future failures could be tracked and compared with expected failures. A number of recommendations resulted from the reevaluation including both increased and decreased surveillance intervals. All recommendations were based on meeting or exceeding existing reliability goals. Considerable cost savings will be incurred upon implementation of the recommendations
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01; 1 as DE87004349.
Files
Additional details
Publishing Information
- Imprint Pagination
- 7 p.
- Report number
- HEDL-SA--3469-FP
Conference
- Title
- Operability of nuclear power systems in normal and adverse environments meeting.
- Dates
- 29 Sep - 3 Oct 1986.
- Place
- Albuquerque, NM (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 18066094
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- EVALUATION; FFTF REACTOR; REACTOR COMPONENTS; REACTOR SHUTDOWN; RELIABILITY; SYSTEMS ANALYSIS
- Descriptors DEC
- EPITHERMAL REACTORS; FAST REACTORS; LIQUID METAL COOLED REACTORS; REACTORS; RESEARCH AND TEST REACTORS; RESEARCH REACTORS; SHUTDOWN; SODIUM COOLED REACTORS; TEST FACILITIES; TEST REACTORS
Optional Information
- Notes
- Portions of this document are illegible in microfiche products.
- Secondary number(s)
- CONF-860908--37.