Published March 1976 | Version v1
Journal article

Comparative study of two mathematical models in the analysis of Gentilly thermal effluents

  • 1. Ecole Polytechnique, Montreal, Quebec (Canada)

Description

Infrared photographic data of the hot water plume at the Gentilly nuclear powerplant were obtained from an aerial survey of the St. Lawrence River. Important parameters such as the longitudinal decrease of temperature or lateral spread of the rejected water became available together with hydraulic and thermal ambient conditions. At first, a three-dimensional model was applied to the actual volume of water rejected, and it predicted a dilution rate much higher than the actual one. The use of a different geometric scheme has reduced the gap between predicted and actual values. The same scheme has been tried on a two-dimensional model. The two-dimensional approach is justified by consideration of the bottom topography. The discussion of results concerns: first, the establishment of an adequate geometric scheme and second, the error brought by the two-dimensional approach. (author)

Additional details

Additional titles

Original title (French)
Etude comparative de deux modeles mathematiques dans l'analyse de rejets thermiques a Gentilly

Identifiers

Publishing Information

Journal Title
Canadian Journal of Civil Engineering
Journal Volume
3
Journal Issue
1
Series
Can. J. Civ. Eng./Rev. Can. Genie Civ.
Journal Page Range
119-125
ISSN
0315-1468

Optional Information

Notes
Updated automatically by Metadata and Full-Text Enrichment Agent