Published 2002 | Version v1
Book

Performance Evaluation of Passive Safety Injection Flow Controllers for the APR1400 Reactor

  • 1. Korea Atomic Energy Research Institute, 150, Dukjin-Dong, Yusong-Gu, Taejon 305-353 (Korea, Republic of)

Description

This paper provides experimental results obtained in the full-scale tests for the performance evaluation of the Fluidic Device which is expected to be adopted in a Korean next generation reactor (APR1400). The tests have been carried out using the full-scale test facility called VAPER (Valve Performance Evaluation test Rig). Following characteristics of the fluidic device are investigated in the present work: peak discharge flow rate, duration of high flow, flow rate switching function, water level depression in stand pipe, etc. Experimental results show that the present fluidic device meets the primary performance requirements of APR1400 plant design. (authors)

Additional details

Publishing Information

Publisher
American Society of Mechanical Engineers - ASME
Imprint Place
New York (United States)
Imprint Pagination
7 p.

Conference

Title
10. international conference on nuclear engineering
Acronym
ICONE-10
Dates
14-18 Apr 2002
Place
Arlington - Virginia (United States)

INIS

Country of Publication
United States
Country of Input or Organization
France
INIS RN
39086271
Subject category
S42: ENGINEERING;
Resource subtype / Literary indicator
Conference
Descriptors DEI
DESIGN; EVALUATION; FLOW RATE; FLUIDIC DEVICES; FUNCTIONS; PERFORMANCE; SAFETY INJECTION; TEST FACILITIES; VALVES; WATER
Descriptors DEC
CONTROL EQUIPMENT; EQUIPMENT; FLOW REGULATORS; HYDROGEN COMPOUNDS; OXYGEN COMPOUNDS