Published 1988 | Version v1
Journal article

Rotating machinery surveillance system reduces plant downtime and radiation exposure

Description

A rotating machinery surveillance system (RMSS) was permanently installed at Grand Gulf nuclear station (GGNS) as part of a program sponsored by the US Department of Energy whose goal was to reduce radiation exposure to power plant personnel resulting from the inspection, maintenance, and repair of rotating machinery. The RMSS was installed at GGNS in 1983 to continuously monitor 173 analog vibration signals from proximity probes mounted on 26 machine trains and ∼450 process data points via a computer data link. Vibration frequency spectra, i.e., the vibration amplitude versus frequency of vibration, and various characterizations of these spectra are the fundamental data collected by the RMSS for performing machinery diagnostics. The RMSS collects vibration frequency spectra on a daily basis for all the monitored rotating equipment and automatically stores the collected spectra for review by the vibration engineer. Vibration spectra automatically stored by the RMSS fall into categories that include the last normal, alarm, minimum and maximum, past three-day data set, baseline, current, and user-saved spectra. During first and second fuel-cycle operation at GGNS, several significant vibration problems were detected by the RMSS. Two of these are presented in this paper: recirculation pumps and turbine-generator bearing degradation. The total reduction in personnel radiation exposure at GGNS from 1985 to 1987 due to the presence of the RMSS was estimated to be in the range from 49 to 54 person-rem

Additional details

Publishing Information

Journal Title
Transactions of the American Nuclear Society
Journal Volume
57
Series
Trans. Am. Nucl. Soc.
Journal Page Range
197-198
ISSN
0003-018X
CODEN
TANSA

Conference

Title
Joint meeting of the European Nuclear Society and the American Nuclear Society.
Dates
30 Oct - 4 Nov 1988.
Place
Washington, DC (USA).

Optional Information

Secondary number(s)
CONF-881011--.