Published 1995 | Version v1
Miscellaneous Restricted

Corrosion problems in the aluminum tank of the reactor of Mexico

Creators

  • 1. National Inst. of Nuclear Research (ININ), Mexico City (Mexico)

Description

The contention developed a leak that was found on March 15th 1985 in a routine inspection to the exposure room. The maximum water leak reached almost 5 liters per hour, it started to diminish until it disappeared completely two months later. It is believed that the holes were blocked by particles in suspension that were introduced to the primary system during the leaking tests. Immediately after the finding of the leak an inspection, testing and repair program was established. Hydrostatic tests to the primary cooling system and cooling system of the exposure room piping showed that the problem was the aluminum liner and not the piping. In order to have the possibility of inspecting the walls of the tank, the pool was drained from its 7.49 m of water down to 3.6 m of depth. At this point the reactor operation stopped and the inspection work started. Previously gamma radiation doses were evaluated using TLD crystals and was determined that 3.6 m of water column gave 0.1 mR/hr of gamma radiation doses at the surface. (orig./HP)

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Part of:
Proceedings of the international topical seminar on management of ageing of research reactors, Geesthacht/Hamburg, May 8-12, 1995

Additional details

Publishing Information

Imprint Title
Proceedings of the international topical seminar on management of ageing of research reactors, Geesthacht/Hamburg, May 8-12, 1995
Imprint Pagination
622 p.
Journal Page Range
p. 275-282.
ISSN
0344-9629
Report number
GKSS--95/E/51

Conference

Title
Topical seminar on management of ageing of research reactors.
Dates
8-12 May 1995.
Place
Geesthacht (Germany).

Optional Information

Secondary number(s)
IAEA-SR--190/29.