Published June 1982 | Version v1
Report Open

Replacement of a cracked pressure tube in Bruce GS unit 2

  • 1. Atomic Energy of Canada Ltd., Sheridan Park, Ontario. Power Projects
  • 2. Ontario Hydro, Toronto (Canada)

Description

In 1982 February, a primary heat transport system leak was detected in the annulus gas system by on-line instrumentation. The source of the leak was found to be a small axial crack in the pressure tube of fuel channel X-14. This fuel channel was removed and replaced by station maintenance staff, and the unit was returned to service five weeks after it had been shut down. The cracked pressure tube was sent to Chalk River Nuclear Laboratories for examination, and the crack was found to be very similar to those found in Pickering GS units 3 and 4 in 1974-75. It was caused by delayed hydride cracking during the period of high residual stress between the time of rolling and the pre-service stress relief

Availability note (English)

MF available from INIS under the Report Number.

Files

15044285.pdf

Files (217.9 kB)

Name Size Download all
md5:f21393853eb8131872abcc6f420e0bcd
217.9 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
10 p.
Report number
AECL--7537

Conference

Title
Canadian Nuclear Society annual conference.
Dates
Jun 1982.
Place
Toronto (Canada).