Description
In 1982 February, a primary heat transport system leak was detected in the annulus gas system by on-line instrumentation. The source of the leak was found to be a small axial crack in the pressure tube of fuel channel X-14. This fuel channel was removed and replaced by station maintenance staff, and the unit was returned to service five weeks after it had been shut down. The cracked pressure tube was sent to Chalk River Nuclear Laboratories for examination, and the crack was found to be very similar to those found in Pickering GS units 3 and 4 in 1974-75. It was caused by delayed hydride cracking during the period of high residual stress between the time of rolling and the pre-service stress relief
Availability note (English)
MF available from INIS under the Report Number.Files
15044285.pdf
Files
(217.9 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:f21393853eb8131872abcc6f420e0bcd
|
217.9 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 10 p.
- Report number
- AECL--7537
Conference
- Title
- Canadian Nuclear Society annual conference.
- Dates
- Jun 1982.
- Place
- Toronto (Canada).
INIS
- Country of Publication
- Canada
- Country of Input or Organization
- Canada
- INIS RN
- 15044285
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- BRUCE-2 REACTOR; FRACTURES; PRESSURE TUBES; REPAIR; SYSTEM FAILURE ANALYSIS
- Descriptors DEC
- CANDU TYPE REACTORS; FAILURES; HEAVY WATER COOLED REACTORS; HEAVY WATER MODERATED REACTORS; NATURAL URANIUM REACTORS; PHWR TYPE REACTORS; POWER REACTORS; PRESSURE TUBE REACTORS; REACTORS; SYSTEMS ANALYSIS; THERMAL REACTORS; TUBES