Monte Carlo study of characteristics of uranium L-edge from X-ray absorption spectrometry
- 1. Korea Institute of Nuclear Nonproliferation and Control, Daejeon (Korea, Republic of)
Description
L-edge densitometry (LED) which is specially called X-ray Absorption Spectrometry (XAS) for uranium xray analysis is a technique of determination of uranium concentration as a continuous x-ray energy beams transmit a uranium liquid sample for safeguard. Compared to K-edge densitometer, since relatively lower energy of uranium L series energy than K series energy, L-edge densitometer does not require a liquid nitride cooling system. In this study, the simulation of uranium L-edge densitometer is performed using Monte Carlo method. Ledge spectrum, such as spectrum jumps, can be confirmed by the simulation. In further study, improvement of counting efficiency through collimation of x-ray, and shielding will be considered for detailed design of L-edge densitometer
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Daejeon (Korea, Republic of)
- Imprint Title
- Proceedings of the KNS 2015 spring meeting
- Imprint Pagination
- [1 CD-ROM]
- Journal Page Range
- [2 p.]
Conference
- Title
- 2015 spring meeting of the KNS
- Dates
- 6-8 May 2015
- Place
- Jeju (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 47023446
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- ABSORPTION; COOLING SYSTEMS; DESIGN; EFFICIENCY; MONTE CARLO METHOD; SHIELDING; SPECTROSCOPY; URANIUM
- Descriptors DEC
- ACTINIDES; CALCULATION METHODS; ELEMENTS; ENERGY SYSTEMS; METALS; SORPTION
Optional Information
- Notes
- 3 refs, 6 figs