Published June 1993 | Version v1
Report

On the recombination model for the energy resolution in ionization chamber filled with liquid Argon or Xenon

  • 1. Saitama Coll. of Health, Urawa (Japan)

Description

By doping liquid Ar with allene or Xe with TEA, the resolution is improved in both liquids. The improvement is significant particularly at the low electric fields. The resolution in the doped Ar or Xe seems to be unchanged for electric fields higher than 4 kV/cm, which is not in agreement with the calculation based on the recombination model. So we must consider models other than recombination model to understand the energy resolution in the liquid chambers. (J.P.N.)

Part of:
Proceedings of the 7. Workshop on Radiation detectors and their uses

Additional details

Publishing Information

Imprint Title
Radiation detectors and their uses
Imprint Pagination
236 p.
Journal Page Range
p. 12-19.
Report number
KEK-PROC--93-8

Conference

Title
7. workshop on radiation detectors and their uses.
Dates
26-27 Jan 1993.
Place
Tsukuba, Ibaraki (Japan).

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
25056193
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ALLENE; ARGON; ELECTRIC FIELDS; ENERGY RESOLUTION; IONIZATION CHAMBERS; LIQUIDS; RECOMBINATION; XENON
Descriptors DEC
DIENES; ELEMENTS; FLUIDS; HYDROCARBONS; MEASURING INSTRUMENTS; NONMETALS; ORGANIC COMPOUNDS; POLYENES; RADIATION DETECTORS; RARE GASES; RESOLUTION

Optional Information