Published December 1997 | Version v1
Report Open

Field test of radioactive high efficiency filter and filter exchange techniques of fuel cycle examination facility

Description

The development of high efficiency filter was started to protect human beings from the contamination of radioactive particles, toxic gases and bacillus, and its gradual performance increment led to the fabrication of Ultra Low Penetration Air Filter (ULPA) today. The application field of ULPA has been spread not only to the air conditioning of nuclear power facilities, semiconductor industries, life science, optics, medical care and general facilities but also to the core of ultra-precision facilities. Periodic performance test on the filters is essential to extend its life-time through effective maintenance. Especially, the bank test on HEPA filter of nuclear facilities handling radioactive materials is required for environmental safety. Nowadays, the bank test technology has been reached to the utilization of a minimized portable detecting instruments and the evaluation techniques can provide high confidence in the area of particle distribution and leakage test efficiency. (author). 16 refs., 13 tabs., 14 figs

Availability note (English)

Available from INIS in electronic form and/or on microfiche .

Files

29025623.pdf

Files (1.2 MB)

Name Size Download all
md5:9edb64866f4bff929cbe8bd7d6a762db
1.2 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
58 p.
Report number
KAERI/TR--943/97

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
29025623
Subject category
S42: ENGINEERING;
Descriptors DEI
AIR FILTERS; EFFICIENCY; FILTRATION; FUEL CYCLE; PERFORMANCE TESTING; RADIOACTIVE MATERIALS; RADIOACTIVITY
Descriptors DEC
EQUIPMENT; FILTERS; MATERIALS; POLLUTION CONTROL EQUIPMENT; SEPARATION PROCESSES; TESTING