Published August 2009 | Version v1
Miscellaneous

Macro damage observation of bearing using portable x-band linac based x-ray source

  • 1. Tokyo Univ., Nuclear Professional School, Tokai, Ibaraki (Japan)

Description

We are developing X-ray nondestructive testing (NDT) system using with portable X-band linac. This system uses 9.4 GHz X-band linac and 250 kW magnetron. Our system energy is 950 keV for Japanese regulation. Therefore we can use it on-site using local radiation protection. We measured electron beam and X-ray. We have started X-ray imaging test. We will use this system for condition based maintenance of pump-impeller at nuclear plants. This linac based X-ray source can generate pulsed X-ray. Therefore we can get still images without stopping rotation when x-ray repetition rate synchronizes impeller's rotation rate. We are successful in proof of principle using a simple fan and a synchronized circuit. We prepare real-time imaging for conventional pump. In this paper, we will explain the detail of this system and experimental results. (author)

Part of:
Proceedings of the 6th annual meeting of Japan Society of Maintenology

Additional details

Additional titles

Original title (Japanese)
Nippon hozen gakkai dai-6-kai gakujutsu koenkai yoshishu

Publishing Information

Imprint Title
Proceedings of the 6th annual meeting of Japan Society of Maintenology
Imprint Pagination
601 p.
Journal Page Range
p. 68-71

Conference

Title
6. annual meeting of Japan Society of Maintenology
Dates
3-5 Aug 2009
Place
Sapporo, Hokkaido (Japan)

Optional Information

Notes
4 refs., 11 figs. Imprint:Nippon hozen gakkai dai-6-kai gakujutsu koenkai yoshishu