Published October 2014 | Version v1
Miscellaneous

Implementation of a dosimetry service for the occupationally exposed personnel of the ESFM-IPN

  • 1. Comision Nacional de Seguridad Nuclear y Salvaguardias, Dr. Barragan No. 779, Col. Narvarte, 03020 Mexico D. F. (Mexico)
  • 2. IPN, Escuela Superior de Fisica y Matematicas, U. P. Adolfo Lopez Mateos, Edif. 9, 07738 Mexico D. F. (Mexico)
  • 3. IPN, Centro de Investigacion en Ciencia y Tecnologia Avanzada, Unidad Legaria, Av. Legaria No. 694, 11500 Mexico D. F. (Mexico)
  • 4. Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

Description

Because the ionizing radiations handling implies a risk for the health, is necessary to take a control of the radiation quantity that the occupationally exposed personnel receives during their daily work with ionizing radiations. For this purpose there are several types of dosimetry and companies that provide the service, but taking advantage that the Escuela Superior de Fisica y Matematicas del Instituto Politecnico Nacional (ESFM-IPN) possesses a thermoluminescence equipment (Tl) was decided to develop a personnel dosimetry service for gammas, with thermoluminescent glasses of type TLD-100. First one carries out a glasses characterization, for which the glasses were washed with a methyl alcohol solution, without rubbing them for not damaging them; after the drying, they were subjected to a temperature of 400 C during one hour and later on 100 grades C for two hours in order to erasing them the bottom information that they could have. 200 glasses were exposed to gamma radiation coming from a Cobalt 60 source property of ESFM-IPN in order to selecting the glasses that had a response whose precision was inside a standard deviation. Of this characterization 80 dosimeters were selected that had better response according to the obtained readings as well as of their shine curves. These selected TLD-100 glasses were irradiated to different dose of gamma radiation and with those readings it was built a dose response curve in m R against readings of electric load in pick Coulombs (pCou). The response curve was a direct line or calibration curve. As final exercise some glasses of this selected lot were subjected to irradiation dose not known by the person that carried out the readings and this way was proven that the results were appropriate with the calibration curve. Finally these dosimeters were placed in port-dosimeters and erased guides of dosimeters, of equipment use and dosimeters lecture were also elaborated. (Author)

Availability note (English)

Available from the Instituto Nacional de Investigaciones Nucleares, Centro de Informacion y Documentacion, 52750 Ocoyoacac, Estado de Mexico (Mexico), e-mail: mclaudia.gonzalez@inin.gob.mx

Additional details

Additional titles

Original title (Spanish)
Implementacion de un servicio de dosimetria para el personal ocupacionalmente expuesto de la ESFM-IPN

Publishing Information

Publisher
Sociedad Nuclear Mexicana
Imprint Place
Mexico D. F. (Mexico)
Imprint Pagination
11 p.

Conference

Title
the nuclear challenges; life extension, safety, public perception and reactors of new generation
Original Conference Title
25. Congreso Anual de la SNM
Acronym
25. SNM Annual Congress; 13. SMSR National Congress
Dates
31 Aug - 4 Sep 2014
Place
Boca del Rio, Veracruz (Mexico)