Published July 18, 2016 | Version v1
Journal article

Diffusion-weighted MR imaging of non-complicated hepatic cysts: Value of 3T computed diffusion-weighted imaging

  • 1. Diagnostic Radiology, Hiroshima University, Hiroshima (Japan)
  • 2. Department of Radiology, Hiroshima University Hospital, Hiroshima (Japan)
  • 3. Radiology, Kure City Medical Association Hospital, Kure (Japan)

Description

To investigate the utility of computed 3T diffusion-weighted imaging (c-DWI) for the diagnosis of non-complicated hepatic cysts with a focus on the T2 shine-through effect. In 50 patients with non-complicated hepatic cysts we acquired one set of DWIs (b-value 0 and 1000 s/mm2) at 1.5T, and two sets at 3T (b-value 0 and 1000 s/mm2, TE 70 ms; b-value 0 and 600 s/mm2, TE 60 ms). We defined the original DWIs acquired with b = 1000 s/mm2 at 1.5T and 3T as "o-1.5T-1000" and "o-3T-1000". c-DWIs were calculated with 3T DWI at b-values of 0 and 600 s/mm2. c-DWI with b = 1000 and 1500 s/mm2 were defined as "c-1000" and "c-1500". Radiologists evaluated the signal intensity (SI) of the cysts using a 3-point score where 1 = not visible, 2 = discernible, and 3 = clearly visible. They calculated the contrast ratio (CR) between the cysts and the surrounding liver parenchyma on each DWIs and recorded the apparent diffusion coefficient (ADC) with a b-value = 0 and 1000 s/mm2 on 1.5T- and 3T DWIs. Compared with o-1.5T-1000 DWI, the visual scores of all but the c-1500 DWIs were higher (p = 0.07 for c-1500- and p < 0.01 for the other DWIs). The CR at b = 1000 s/mm2 was higher on o-3T-1000- than on o-1.5T-1000- (p < 0.01) but not higher than on c-1500 DWIs (p = 0.96). The CR at b = 0 s/mm2 on 3T images with TE 70 ms was higher than on 1.5T images (p < 0.01). The ADC value was higher for 3T- than 1.5T images (p < 0.01). Non-complicated hepatic cysts showed higher SI on o-3T-1000- than o-1.5T-1000 DWIs due to the T2-shine through effect. This high SI was suppressed on c-1500 DWIs

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ejro.2016.07.001; Available from http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4959945

Additional details

Publishing Information

Journal Title
European Journal of Radiology Open
Journal Volume
3
Journal Page Range
p. 138-144
ISSN
2352-0477

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
47117608
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BIOMEDICAL RADIOGRAPHY; CYSTS; DIFFUSION; IMAGES; LIVER; MAGNETIC RESONANCE; NMR IMAGING; SIGNAL-TO-NOISE RATIO
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; DIMENSIONLESS NUMBERS; GLANDS; MEDICINE; NUCLEAR MEDICINE; ORGANS; PATHOLOGICAL CHANGES; RADIOLOGY; RESONANCE

Optional Information

Copyright
Copyright (c) 2016 The Author(s)
Notes
PMCID: PMC4959945; PMID: 27489867; PUBLISHER-ID: S2352-0477(16)30022-3; OAI: oai:pubmedcentral.nih.gov:4959945; This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).