Published March 1989
| Version v1
Journal article
Fast high voltage pulsers for nuclear instruments
- 1. Tokyo Univ. (Japan). Faculty of Engineering
Description
Fast high voltage pulsers having been developed and used in our facility are described. They include (a) a high voltage pulser achieving 0.5 ns rise time (800 V), (b) a needle pulser featuring very narrow width of 1.5 ns (200 V across a 5 ohms load), (c) a pulser featuring continuously-variable pulse width (210 V, 50 ohms, rise time=3 ns, fall time=3 ns), (d) an easy-to-handle 500 V pulser (rise time=50 ns), and (e) a 2kV pulser with rise time of 2μs, using VMOS-FETs and a transformer. (author)
Additional details
Publishing Information
- Journal Title
- Journal of the Faculty of Engineering, University of Tokyo, Series B
- Journal Volume
- 40
- Journal Issue
- 1
- Series
- J. Fac. Eng., Univ. Tokyo, Ser. B.
- Journal Page Range
- 1-8
- ISSN
- 0563-7937
- CODEN
- JETBA
INIS
- Country of Publication
- Japan
- Country of Input or Organization
- Japan
- INIS RN
- 21037025
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- ELECTRIC POTENTIAL; FABRICATION; MOSFET; PULSE GENERATORS; PULSE RISE TIME; SPECIFICATIONS; TRANSFORMERS
- Descriptors DEC