MRI assessment of bone marrow oedema in the sacroiliac joints of patients with spondyloarthritis: is the SPAIR T2w technique comparable to STIR?
Creators
- 1. University of Sao Paulo, Division of Radiology, Department of Internal Medicine, Ribeirao Preto Medical School, Ribeirao Preto, SP (Brazil)
- 2. University of Sao Paulo, Division of Clinical Imunology, Department of Internal Medicine, Ribeirao Preto Medical School, Ribeirao Preto, SP (Brazil)
- 3. Hospital do Coracao (HCor) e Teleimagem, Departamento de Radiologia, Sao Paulo, SP (Brazil)
- 4. Boston University School of Medicine, Department of Radiology, Quantitative Imaging Center, Boston, MA (United States)
- 5. Hopital Saint-Antoine, Universite Paris VI, Service de Radiologie, Paris (France)
- 6. University of Sao Paulo, Department of Internal Medicine, Ribeirao Preto Medical School, Ribeirao Preto, SP (Brazil)
Description
To compare short tau inversion-recovery (STIR) with another fat saturation method in the assessment of sacroiliac joint inflammation. This prospective cross-sectional study comprised 76 spondyloarthritis (SpA) patients who underwent magnetic resonance imaging of the sacroiliac joints in a 1.5-T scanner, using STIR, spectral attenuated inversion recovery (SPAIR) T2w and spectral presaturation with inversion recovery (SPIR) T1w post-contrast sequences. Two independent readers (R1 and R2) assessed the images using the Spondyloarthritis Research Consortium of Canada (SPARCC) score. We assessed agreement of the SPARCC scores for SPAIR T2w and STIR with that for T1 SPIR post-contrast (reference standard) using the St. Laurent coefficient. We evaluated each sequence using the concordance correlation coefficient (CCC). We observed a strong agreement between STIR and SPAIR T2w sequences. Lin's CCC was 0.94 for R1 and 0.84 for R2 for STIR and 0.94 for R1 and 0.84 for R2 for SPAIR. The interobserver evaluation revealed a good CCC of 0.79 for SPAIR and 0.78 for STIR. STIR technique and SPAIR T2w sequence showed high agreement in the evaluation of sacroiliac joint subchondral bone marrow oedema in patients with SpA. SPAIR T2w may be an alternative to the STIR sequence for this purpose. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-017-4746-7Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 27
- Journal Issue
- 9
- Journal Page Range
- p. 3669-3676
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 48084139
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BONE JOINTS; BONE MARROW; COMPARATIVE EVALUATIONS; DIAGNOSIS; EDEMA; IMAGE PROCESSING; INFLAMMATION; MAGNETIC FIELDS; NMR IMAGING; PELVIS; RELAXATION TIME; RHEUMATIC DISEASES; SPONDYLITIS; WEIGHTING FUNCTIONS
- Descriptors DEC
- ANIMAL TISSUES; BODY; DIAGNOSTIC TECHNIQUES; DISEASES; EVALUATION; FUNCTIONS; HEMATOPOIETIC SYSTEM; ORGANS; PATHOLOGICAL CHANGES; PROCESSING; RHEUMATIC DISEASES; SKELETAL DISEASES; SKELETON; SYMPTOMS