Description

At Ohi Power Station Unit No. 2, during operation at the 100% output (1,175 MW), a high alarm on B main steam line monitor (N-16 monitor: R-66H) actuated on February 25, 1995 due to B-Steam Generator (S/G) tube leakage. Then the reactor was manually shut down. The results of the investigation of S/G tube leakage and countermeasures are shown in this report

Additional details

Publishing Information

Publisher
American Society of Mechanical Engineers.
Imprint Place
New York, NY (United States)
ISBN
0-7918-1226-X
Imprint Title
ICONE-4: Proceedings. Volume 5: Radioactive waste disposal; Decontamination and decommissioning; Aging assessment and license renewals; Global advances in nuclear codes and standards; Major component reliability
Imprint Pagination
525 p.
Journal Page Range
p. 345-350.

Conference

Title
ASME/JSME international conference on nuclear engineering.
Acronym
ICONE 4
Dates
10-13 Mar 1996.
Place
New Orleans, LA (United States).

Optional Information

Secondary number(s)
CONF-960306--.