Published August 2012 | Version v1
Journal article

The application of chemical-ultrasonic-decontamination to RCP inner part

Creators

  • 1. Nuclear Power Operations Management Co., Ltd., Haiyan (China)
  • 2. College of Mechanical Engineering Zhejiang University of Technology, Hangzhou (China)

Description

This article introduces the application of chemical-ultrasonic-decontamination during Qinshan unclear power plant overhaul maintenance, which can reduce the dose rate from RCP inner parts below 0.3 mSv/h, so as to meet the maintenance protection requirements at short-distance operation. (author)

Additional details

Publishing Information

Journal Title
Radiation Protection Bulletin
Journal Volume
32
Journal Issue
4
Journal Page Range
p. 29-31
ISSN
1004-6356

INIS

Country of Publication
China
Country of Input or Organization
China
INIS RN
50042390
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Descriptors DEI
COOLANTS; DECONTAMINATION; DISTANCE; DOSE RATES; MAINTENANCE; NUCLEAR POWER PLANTS; OPERATION; PUMPS; SAFETY; ULTRASONIC WAVES
Descriptors DEC
CLEANING; EQUIPMENT; NUCLEAR FACILITIES; POWER PLANTS; SOUND WAVES; THERMAL POWER PLANTS

Optional Information

Notes
2 figs., 2 tabs., 5 refs.