Increasing the operational safety of nuclear facilities by using special insulation parts in the containment zone

Creators

  • 1. Tyco Electronics Raychem GmbH, Ottobrunn (Germany)

Description

LOCA (Loss of coolant accident) resistant heat-shrinkable polymeric products are widely used for the connection of LV cables for class 1E systems inside the containment area of nuclear power plants. The paper/presentation describes the verification of a reformulated compound for these products, where certain components of the compound formulation had to be substituted. A qualification programme with this so-called reformulated compound was undertaken to proof the equivalency of the products to the products made out of the original compound. The basic elements of this requalification project were material qualification tests including accelerated aging tests according to the arrhenius method and type tests in accordance to IEEE 383, including flammability tests. The test results showed that the products made out of the reformulated compound were similar in fit, form and function to the original products. Additional tests have also proven higher application ranges for the heat-shrinkable tubings and the successful evaluation of a design for a medium voltage joint design for LOCA resistant application. (author)

Availability note (English)

Available from INIS in electronic form

Files

36108748.pdf

Files (386.9 kB)

Name Size Download all
md5:0a13f5889807e3b26924240dad3d7007
386.9 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
9 p.
Report number
INIS-BG--0990

Conference

Title
The Future of Nuclear Energy on the Balkans: Security of Energy Supply and Nuclear New Builds
Acronym
BULATOM International Nuclear Forum
Dates
15-18 Jun 2005
Place
Varna (Bulgaria)

INIS

Country of Publication
Bulgaria
Country of Input or Organization
Bulgaria
INIS RN
36108748
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
AGING; ELECTRIC CABLES; FLAMMABILITY; LOSS OF COOLANT; MATERIALS TESTING; POLYMERS; REACTOR SAFETY; REACTORS
Descriptors DEC
ACCIDENTS; CABLES; COMBUSTION PROPERTIES; CONDUCTOR DEVICES; ELECTRICAL EQUIPMENT; EQUIPMENT; REACTOR ACCIDENTS; SAFETY; TESTING

Optional Information

Notes
7 figs.