Published December 2012 | Version v1
Journal article

Structural damage monitoring of harbor caissons with interlocking condition

  • 1. Pukyong National Univ., Busan (Korea, Republic of)

Description

The objective of this study is to monitor the health status of harbor caissons which have potential foundation damage. To obtain the objective, the following approaches are performed. Firstly, a structural damage monitoring(SDM) method is designed for interlocked multiple caisson structures. The SDM method utilizes the change in modal strain energy to monitor the foundation damage in a target caisson unit. Secondly, a finite element model of a caisson system which consists of three caisson units is established to verify the feasibility of the proposed method. In the finite element simulation, the caisson units are constrained each other by shear key connections. The health status of the caisson system against various levels of foundation damage is monitored by measuring relative modal displacements between the adjacent caissons

Additional details

Publishing Information

Journal Title
Journal of the Korean Society for Nondestructive Testing
Journal Volume
32
Journal Issue
6
Series
15 refs, 7 figs, 1 tab
Journal Page Range
p. 678-685
ISSN
1225-7842

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
44050271
Subject category
S42: ENGINEERING;
Descriptors DEI
COMPUTERIZED SIMULATION; DAMAGE; DESIGN; FEASIBILITY STUDIES; FINITE ELEMENT METHOD; MONITORING
Descriptors DEC
CALCULATION METHODS; MATHEMATICAL SOLUTIONS; NUMERICAL SOLUTION; SIMULATION