Published December 15, 2003 | Version v1
Journal article

Analysis of low Z elements on Si wafer surfaces with synchrotron radiation induced total reflection X-ray fluorescence at SSRL, Beamline 3-3: comparison of droplets with spin coated wafers

Description

The unique properties of synchrotron radiation, such as high incident flux combined with low divergence, its linear polarization and energy tunability, make it an ideal excitation source for total reflection X-ray fluorescence (TXRF) spectroscopy in order to non-destructively detect trace impurities of transition metals on Si wafer surfaces. When used with a detector suitable for the determination of low energy radiation this technique can be extended to the detection of low-Z elements, such as Al, Na and Mg. Experiments have been performed at SSRL Beamline 3-3, a bending magnet beamline using monochromatic radiation from a double multilayer monochromator. The wafer was mounted vertically in front of the detector, which was aligned along the linear polarization vector of the incoming synchrotron radiation. This configuration allows the detector to accept a large solid angle as well as to take advantage of the reduced scattered X-ray intensity emitted in the direction of the linear polarization vector. A comparison between droplet samples and spin coated samples was done, in order to compare the capabilities of vapor phase decomposition (VPD-TXRF) with conventional SR-straight-TXRF. Detection limits in the range of 50 fg corresponding to 2E10 atoms/cm2 have been obtained for Na. The spin coated samples, prepared from solutions containing an equal amount of Na, Mg and Al showed an unexpected result when performing a scan of the angle of incidence of the incoming X-rays suggesting a different adsorption behavior of the elements in a multielement solution on the wafer surface. The observation of this behavior is important because the spin coating technique is the standard method for the preparation of surface standards in semiconductor quality control. This effect could be characteristic of the Na, Mg, Al solution used, but the angle dependence of the fluorescence signal of a standard should always be investigated before using the standard for calibration of the apparatus and quantification

Additional details

Identifiers

DOI
10.1016/S0584-8547(03)00218-0;
arXiv
arXiv:cond-mat/9906338v1;
PII
S0584854703002180;

Publishing Information

Journal Title
Spectrochimica Acta. Part B, Atomic Spectroscopy
Journal Volume
58
Journal Issue
12
Journal Page Range
p. 2105-2112
ISSN
0584-8547
CODEN
SAASBH

Conference

Title
9. symposium on total reflection X-ray analysis and related methods
Dates
8-13 Sep 2002
Place
Madeira (Portugal)

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
35045999
Subject category
S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ALUMINIUM; COMPARATIVE EVALUATIONS; DROPLETS; MAGNESIUM; MULTI-ELEMENT ANALYSIS; QUANTITATIVE CHEMICAL ANALYSIS; REFLECTION; SENSITIVITY; SILICON; SODIUM; TRACE AMOUNTS; X-RAY FLUORESCENCE ANALYSIS
Descriptors DEC
ALKALI METALS; ALKALINE EARTH METALS; CHEMICAL ANALYSIS; ELEMENTS; EVALUATION; METALS; NONDESTRUCTIVE ANALYSIS; PARTICLES; SEMIMETALS; X-RAY EMISSION ANALYSIS

Optional Information

Copyright
Copyright (c) 2003 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.