Published October 2017 | Version v1
Journal article

Conceptual design of BNCT facility based on the TRR medical room

  • 1. Department of physics, Shahrood University of Technology, Shahrood (Iran, Islamic Republic of)
  • 2. Reactor Research School, Nuclear Science and Technology Research Institute of Iran, Tehran (Iran, Islamic Republic of)

Description

This paper presents a conceptual design of the Boron Neutron Capture Therapy (BNCT) facility based on the medical room of Tehran Research Reactor (TRR). The medical room is located behind the east wall of the reactor pool. The designed beam line is an in-pool Beam Shaping Assembly (BSA) which is considered between the reactor core and the medical room wall. The final designed BSA can provide 2.96× 109 n/cm2⋅s epithermal neutron flux at the irradiation position with acceptable beam contamination to use as a clinical BNCT.

Availability note (English)

Available from http://dx.doi.org/10.1088/1748-0221/12/10/P10018

Additional details

Publishing Information

Journal Title
Journal of Instrumentation
Journal Volume
12
Journal Issue
10
Journal Page Range
p. P10018
ISSN
1748-0221