Published November 2015
| Version v1
Journal article
Analysis of earthquake in building structure gamma irradiator capacity 2 MCi
Creators
- 1. Pusat Rekayasa Fasilitas Nuklir (PRFN) - BATAN, Kawasan Puspiptek Serpong, Tangerang Selatan 15314 (Indonesia)
Description
Construction of irradiation building must be calculated on the weight load carried by the structure of the building both live loads and dead loads. Loads include wind, earthquake, tornado and load of building itself. External load is a load that comes from outside the building load including soil resistance factors, while internal loads are its own weight and the weight are borne in the building. Calculation of earthquake loads must be considered in combination with the reduced live load and dead load. Similarly to the effect of the structure due to the reduction or shrinkage that occurs as a result of temperature change. Calculation of loading based on the loading for building regulations in Indonesia. (author)
Additional details
Additional titles
- Original title (Indonesian)
- Analisis gempa pada struktur gedung iradiator gamma kapasitas 2 MCi
Publishing Information
- Journal Title
- Jurnal Perangkat Nuklir
- Journal Volume
- 09
- Journal Issue
- 2
- Journal Page Range
- p. 80-90
- ISSN
- 1978-3515
INIS
- Country of Publication
- Indonesia
- Country of Input or Organization
- Indonesia
- INIS RN
- 51102244
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Descriptors DEI
- BUILDINGS; CAPACITY; COMPRESSION; COMPUTER CALCULATIONS; CONSTRUCTION; DESIGN; EARTHQUAKES; REGULATIONS; STRESSES
- Descriptors DEC
- LAWS; SEISMIC EVENTS
Optional Information
- Notes
- 10 refs.; 2 tabs.; 6 figs.