Fluid-structure interaction analysis of a water pool under loading caused by a condensation-induced water hammer

Description

A coupled fluid-structure interaction calculation was performed with Star-CD and ABAQUS, which were coupled with the ES-FSI code. The motion of the wall of a test pool during a rapid bubble collapse was solved and taken into account during the CFD calculation. A fluid-structure interaction analysis was also conducted, in which the stationary state of the pool due to a gravity load was calculated. In addition, methods for estimating pressure loads in a water pool during steam injection were investigated. The Method of Images (MOI) for calculating the pressure loads during a steam bubble collapse was implemented and tested for the POOLEX experiment. The first version of the homogeneous two-phase model was implemented for the Star-CD CFD code and tested in the quasistationary situation, where the steam that was blown down into a water pool was condensing inside the vertical blowdown pipe. (au)

Files

36058893.pdf

Files (17.8 MB)

Name Size Download all
md5:1c3cd51cd3d431037edee56c8a9d43cd
17.8 MB Preview Download

System files (3.5 kB)

Name Size Download all

Additional details

Publishing Information

ISBN
87-7893-163-0
Imprint Pagination
60 p.
Report number
NKS--104

Optional Information

Contract/Grant/Project number
Contract NKS-R-2002-1
Notes
5 tabs., 26 ills., 19 refs.