Published 2009 | Version v1
Miscellaneous

Measurement of isochronism of RIBF cyclotrons

  • 1. RIKEN, Nishina Center for Accelerator-Based Science, Wako, Saitama (Japan)

Description

The 6-20 phase probes (PPs) are installed in the all cyclotrons of RIBF for non-destructive measurement of their isochronism. We have measured isochronism by observing the zero-cross points of bunch signals from PPs using an oscilloscope for nearly 20 years. We have developed new measuring system of isochronism using a lock-in amplifier for commissionings of 3 new cyclotrons started at 2006. In order to investigate the consistency of those two measuring methods of isochronism, we measured the isochronism using an oscilloscope and lock-in amplifier simultaneously. Additionally, we have performed Fourier analysis to bunch signals observed using an oscilloscope to investigate the difference of beam phases between frequency components. (author)

Part of:
Proceedings of the 6th annual meeting of Particle Accelerator Society of Japan

Additional details

Additional titles

Original title (Japanese)
Dai 6 kai nippon kasokuki gakkai nenkai

Publishing Information

Imprint Title
Proceedings of the 6th annual meeting of Particle Accelerator Society of Japan
Imprint Pagination
1177 p.
Journal Page Range
p. 25-29

Conference

Title
6. annual meeting of Particle Accelerator Society of Japan
Dates
5-7 Aug 2009
Place
Tokai, Ibaraki (Japan)

INIS

Optional Information

Notes
This CD-ROM can be used for WINDOWS, MACINTOSH; Acrobat Reader is included; Data in PDF format, Folder Name: papers, Paper ID: woopb03.pdf; 3 refs., 12 figs., 1 tab. Imprint:Dai 6 kai nippon kasokuki gakkai nenkai