Effect of phantom voxelization in CT simulations
- 1. Crump Institute for Molecular Imaging, University of California at Los Angeles School of Medicine, Los Angeles, California 90095 (United States)
- 2. Department of Biomedical Engineering, University of California, Davis, Davis, California 95616 (United States)
- 3. Image Sciences Institute, Utrecht University Hospital, Utrecht (Netherlands)
Description
In computer simulations of x-ray CT systems one can either use continuous geometrical descriptions for phantoms or a voxelized representation. The voxelized approach allows arbitrary phantoms to be defined without being confined to geometrical shapes. The disadvantage of the voxelized approach is that inherent errors are introduced due to the phantom voxelization. To study effects of phantom discretization, analytical CT simulations were run for a fan-beam geometry with phantom voxel sizes ranging from 0.0625 to 2 times the reconstructed pixel size and noise levels corresponding to 103-107 photons per detector pixel prior to attenuation. The number of rays traced per detector element was varied from 1 to 16. Differences in the filtered backprojection images caused by changing the phantom matrix sizes and number of rays traced were assessed by calculating the difference between reconstructions based on the finest matrix and coarser matrix simulations. In noise free simulations, all phantom matrix sizes produced a measurable difference in comparison with the finest phantom matrix used. When even a small amount of noise was added to the projection data, the differences due to the phantom discretization were masked by the noise, and in all cases there was almost no improvement by using a phantom matrix that was more than twice as fine as the reconstruction matrix. No substantial improvement was achieved by tracing more than 4 rays per detector pixel
Additional details
Identifiers
- DOI
- 10.1118/1.1461841;
Publishing Information
- Journal Title
- Medical Physics
- Journal Volume
- 29
- Journal Issue
- 4
- Journal Page Range
- p. 492-498
- ISSN
- 0094-2405
- CODEN
- MPHYA6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 35004199
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ATTENUATION; COMPUTERIZED TOMOGRAPHY; IMAGE PROCESSING; NOISE; PHANTOMS
- Descriptors DEC
- DIAGNOSTIC TECHNIQUES; MOCKUP; PROCESSING; STRUCTURAL MODELS; TOMOGRAPHY
Optional Information
- Notes
- (c) 2002 American Association of Physicists in Medicine.