Published April 2002 | Version v1
Journal article

Effect of phantom voxelization in CT simulations

  • 1. Crump Institute for Molecular Imaging, University of California at Los Angeles School of Medicine, Los Angeles, California 90095 (United States)
  • 2. Department of Biomedical Engineering, University of California, Davis, Davis, California 95616 (United States)
  • 3. Image Sciences Institute, Utrecht University Hospital, Utrecht (Netherlands)

Description

In computer simulations of x-ray CT systems one can either use continuous geometrical descriptions for phantoms or a voxelized representation. The voxelized approach allows arbitrary phantoms to be defined without being confined to geometrical shapes. The disadvantage of the voxelized approach is that inherent errors are introduced due to the phantom voxelization. To study effects of phantom discretization, analytical CT simulations were run for a fan-beam geometry with phantom voxel sizes ranging from 0.0625 to 2 times the reconstructed pixel size and noise levels corresponding to 103-107 photons per detector pixel prior to attenuation. The number of rays traced per detector element was varied from 1 to 16. Differences in the filtered backprojection images caused by changing the phantom matrix sizes and number of rays traced were assessed by calculating the difference between reconstructions based on the finest matrix and coarser matrix simulations. In noise free simulations, all phantom matrix sizes produced a measurable difference in comparison with the finest phantom matrix used. When even a small amount of noise was added to the projection data, the differences due to the phantom discretization were masked by the noise, and in all cases there was almost no improvement by using a phantom matrix that was more than twice as fine as the reconstruction matrix. No substantial improvement was achieved by tracing more than 4 rays per detector pixel

Additional details

Identifiers

Publishing Information

Journal Title
Medical Physics
Journal Volume
29
Journal Issue
4
Journal Page Range
p. 492-498
ISSN
0094-2405
CODEN
MPHYA6

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
35004199
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
ATTENUATION; COMPUTERIZED TOMOGRAPHY; IMAGE PROCESSING; NOISE; PHANTOMS
Descriptors DEC
DIAGNOSTIC TECHNIQUES; MOCKUP; PROCESSING; STRUCTURAL MODELS; TOMOGRAPHY

Optional Information

Notes
(c) 2002 American Association of Physicists in Medicine.