Published December 1, 1992 | Version v1
Journal article

The KEDR drift chamber

Description

The design features of the KEDR drift chamber are described. The 1 m long and 1 m outer diameter cylindrical chamber consists of seven radial super layers. The multiwire drift cell contains six sense wires with a distance of 4.5 mm. The maximum drift distance is 30 mm. Measurements of spatial resolution and aging tests were performed using DME gas with a prototype. The resolution averaged over drift distance has a value of 40 μm. The relative gain drop is equal to 45%/(C/cm). This would correspond to 2% pulse height decrease per year at a gas gain of 105 and flux of the charged particles of 1 kHz/cm2. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A
Journal Volume
323
Journal Issue
1/2
Journal Page Range
p. 151-156.
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
Wire chambers - recent trends and alternative techniques.
Acronym
6. international wire chamber conference (WCC-6)
Dates
17-21 Feb 1992.
Place