Published April 1980
| Version v1
Journal article
Effect of temperature on characteristic of self-powered detectors
Description
Self-powered detectors (SPD) are used extensively in systems for in-reactor monitoring of the distribution of energy release in nuclear reactors. Experience gained from the use of SPD in power reactors showed that they operate stably at a temperature reaching 700/degree/C and no temperature instability of the sensitivity was observed. Here a special study is reported of the influence of temperature on the readings of SPD. 7 refs
Additional details
Publishing Information
- Journal Title
- Sov. At. Energy (Engl. Transl.)
- Journal Volume
- 48
- Journal Issue
- 4
- Series
- Sov. At. Energy (Engl. Transl.).
- Journal Page Range
- 263-266
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 13684545
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- NEUTRON FLUX; REACTOR INSTRUMENTATION; SELF-POWERED DETECTORS; TEMPERATURE DEPENDENCE
- Descriptors DEC
- MEASURING INSTRUMENTS; RADIATION DETECTORS; RADIATION FLUX