The test results of the HF power generator of a meson-factory accelerator first section

Description

The results obtained in testing a power HF generator of the first section of a meson factory accelerator (rated pulse output power 4 MW, mean power 130 kW, and pulse duration 300 μs) are presented. In order to test the HF generator at rated pulse and mean powers, the resonator has been shunted by a load equivalent with controlled coupling. The HF generator has been operated in two modes: with external excitation from a generator with adjustable frequency and with a self-oscillation with positive feedback via the resonator. Initial generator switchings have resulted in a multipactoring in the resonator with the fields being by two orders less than the rated values. Stable generator operation without breakdowns is achieved at rated and increased (up to 5 MW) pulse and average (up to 200 kW) powers. Tests have shown that the difficulties of controlling the HF channel, caused by the observed parasitic SHF self-excitation of the triode, can be overcome by using a circuit with control of the anode voltage

Additional details

Additional titles

Original title (Russian)
Результаты испытаний мощного генератора первой части ускорителя мезонной фабрики

Publishing Information

Imprint Title
Radio-frequency systems of charged particle accelerators
Journal Issue
no. 28
Series
Trudy Radiotekhnicheskogo Instituta AN SSSR.
Journal Page Range
p. 53-59.
Report number
INIS-mf--5287

INIS

Country of Publication
USSR
Country of Input or Organization
USSR
INIS RN
11508806
Subject category
S43: PARTICLE ACCELERATORS;
Descriptors DEI
AMPLITUDES; ELECTRIC FIELDS; HIGH FREQUENCY AMPLIFIERS; LINEAR ACCELERATORS; PERFORMANCE TESTING; RF SYSTEMS
Descriptors DEC
ACCELERATORS; AMPLIFIERS; TESTING

Optional Information

Notes
3 refs.; 2 figs.; 1 table. Imprint:Vysokochastotnye ustrojstva uskoritelej zaryazhennykh chastits.