Published June 1992 | Version v1
Report Restricted

Field calculation of D0 toroids and comparison with measurement

Description

The magnetic structure of the D0 detector is described in an earlier report. The two-dimensional code POISSON was used for the initial design of the magnetic structures and the magnetic properties of the D0 toroids. During the construction, the two-dimensional code ANSYS was used to perform more detailed calculations. Full three-dimensional analysis was also performed using the code TOSCA. These new results are reported here and compared with measurements. In this study the magnetic flux in all toroids, CF, EF, and SAMUS is set in the same direction

Availability note (English)

MF available from INIS under the Report Number; OSTI as DE92016350; NTIS; INIS; US Govt. Printing Office Dep.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
28 p.
Report number
FNAL-TM--1786

Optional Information

Contract/Grant/Project number
Contract AC02-76CH03000
Funding organization
USDOE, Washington, DC (United States).