Published May 1998 | Version v1
Report Open

Structural evaluation report of piping and support structure for design-changed hot-water layer system

Description

After hot-water layer system had been installed, the verification tests to reduce the radiation level at the top of reactor pool were performed many times. The major goal of this report is to assess the structural integrity on the piping and the support structures of design-changed hot-water layer system. The piping stress analysis was performed by using ADLPIPE program for the pump suction line and the pump discharge line subjected to dead weight, pressure, thermal expansion and seismic loadings. The stress analysis of the support structure was carried out using the reaction forces obtained from the piping stress analysis. The results of structural evaluation for the pipings and the support structures showed that the structural acceptance criteria were satisfied, in compliance with ASME, subsection ND for the piping and subsection NF for the support structures. Therefore based on the results of the analysis and the design, the structural integrity on the piping and the support structures of design-changed hot-water system was proved. (author). 9 refs., 9 tabs., 14 figs

Availability note (English)

Available from INIS in electronic form

Files

30045496.pdf

Files (1.6 MB)

Name Size Download all
md5:c8541af71228eac1fecad2d24ce36b9b
1.6 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
125 p.
Report number
KAERI/TR--1048/98