Detection of cracks with low vertical offset in clayey formations from galleries by using seismic methods. Tournemire experimental station. First part: problem analysis and measurement sizing

  • 1. Institut de Radioprotection et de Surete Nucleaire - IRSN, Pole radioprotection, environnement, dechets et crise, Service de caracterisation des sites et des aleas naturels, Bureau d'evaluation des Risques sismiques pour la Surete des Installations Nulceaires, 31, av. de la Division Leclerc 92260 Fontenay-aux-Roses (France)
  • 2. Institut Francais des Sciences et Technologies des Transports, de l'Amenagement et des Reseaux - IFSTTAR, Departement Mesure Auscultation et Calcul Scientifique, Service Auscultation et Imagerie, Cite Descartes, Boulevard Newton F-77 Champs-sur-Marne (France)

Description

Within the frame of the expertise of the ANDRA file on the project of storage of radioactive wastes in clayey formations, the detection of natural cracks which could locally alter the argillite containment properties is a crucial issue. As some previous studies showed that some cracks exhibiting a low vertical offset could not be detected in clayey formations from the surface, this document reports a study which aimed at assessing the possibility of detection of such a crack by means of seismic methods directly implemented from underground works. It reports a detailed analysis of the seismic imagery problem, the characterization of different areas of the investigated environment, the assessment and validation of various hypotheses by using experimental data obtained in an experimental station and numerical simulations. The potential of each envisaged method (migration, tomography, wave form inversion) is assessed, notably with respect to synthetic seismic data obtained by numerical modelling. Preliminary results are used to size a complete seismic measurement campaign aimed at the characterization of the crack area, and at the assessment of detection limitations of the different methods

Files

46058469.pdf

Files (9.0 MB)

Name Size Download all
md5:8fada8419970247f18806a73c88fea7f
9.0 MB Preview Download

Additional details

Additional titles

Original title (French)
Detection de failles a faible decalage vertical dans le milieu argileux depuis les galeries par des methodes sismiques: Station experimentale de Tournemire. Premiere partie: Analyse du probleme et dimensionnement des mesures

Publishing Information

Imprint Pagination
69 p.
Report number
IRSN-RT-PRP-DGE--2012-00001

Optional Information

Notes
66 refs.; Available from the INIS Liaison Officer for France, see the 'INIS contacts' section of the INIS website for current contact and E-mail addresses: http://www.iaea.org/inis/Contacts/