Published August 2010 | Version v1
Journal article

Reproducibility and accuracy of ABC/2 and 3D techniques in ICH volume measurement

  • 1. Neuroradiology Department, National Neuroscience Institute, Singapore 308433 (Singapore)
  • 2. Charles Sturt University, Wagga Wagga, NSW 2650 (Australia)

Description

Purpose: The aims of this study were to validate 3D volume measurement and to compare ICH volume determined by conventional measurements. Materials and methods: Data of all 50 patients were retrospectively collected. The ICH volume was compared using ABC/2 technique and 3D volumetric technique by two observers. Interobserver and intraobserver variations were calculated. Variability of measurements was analysed. Results: The mean volume was 41.43 ± 3.0 mm3 using 3D technique versus 45.37 ± 3.9 mm3 using ABC/2 technique. The coefficients of variation for interobserver and intraobserver variability of 3D and ABC/2 technique were 5.03% versus 6.28% and 2.78% versus 8.77%. ABC/2 technique generally overestimated ICH volume. The 95% confidence interval (CI) of 3D and ABC/2 technique was 29.4-53.5 mm3 and 32-58.6 mm3. There was no significance difference in volume measurement by variance ratio test (F-test), where p = 0.527. The correlation coefficient of ABC/2 and 3D method was 0.99 (p < 0.001, 95% CI 0.98-0.99). Box-and-whisker graph showed that ABC/2 technique generally overestimated the ICH volume with irregular margin. The results showed that (a) ICH volumes estimated by the ABC/2 technique do not significantly differ from 3D technique. (b) ABC/2 technique was accurate when estimating volume with regular margin but overestimated volume in irregular margin. (c) Reproducibility of 3D technique in ICH volume with irregular margin was higher. (d) Reproducibility of ABC/2 technique in ICH volume with regular margin was higher. Conclusions: 3D technique is the most reproducible technique. Although the ABC/2 technique slightly overestimates ICH volume with irregular margin, the difference was not significant. In view of the software requirement for 3D measurement, ABC/2 technique is considered a rapid and reliable volume measurement technique.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radi.2010.04.004

Additional details

Identifiers

DOI
10.1016/j.radi.2010.04.004;
PII
S1078-8174(10)00048-9;

Publishing Information

Journal Title
Radiography (London 1995)
Journal Volume
16
Journal Issue
3
Journal Page Range
p. 209-216
ISSN
1078-8174

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
42054297
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
CORRELATIONS; HEMORRHAGE; THREE-DIMENSIONAL CALCULATIONS; VOLUME
Descriptors DEC
PATHOLOGICAL CHANGES; SYMPTOMS

Optional Information

Copyright
Copyright (c) 2010 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.