Published October 3, 2011 | Version v1
Journal article

The impact of water and hydrocarbon concentration on the sensitivity of a polymer-based quartz crystal microbalance sensor for organic compounds

  • 1. CSIRO, Earth Science and Resource Engineering, PO Box 1130, Bentley, WA 6102 (Australia)
  • 2. CSIRO, Materials Science and Engineering, Locked Bag 33, Clayton Sth MDC, Vic 3169 (Australia)
  • 3. University of Western Australia, School of Biomedical, Biomolecular and Chemical Sciences, Crawley, WA 6009 (Australia)

Description

Highlights: → The response of a polymer coated QCM sensor is affected by water soaking time. → Polymer-water interfacial processes influence the QCM sensitivity for hydrocarbons. → The QCM sensitivity of high Tg polymer films is affected by plasticization processes. - Abstract: Long-term environmental monitoring of organic compounds in natural waters requires sensors that respond reproducibly and linearly over a wide concentration range, and do not degrade with time. Although polymer coated piezoelectric based sensors have been widely used to detect hydrocarbons in aqueous solution, very little information exists regarding their stability and suitability over extended periods in water. In this investigation, the influence of water aging on the response of various polymer membranes [polybutadiene (PB), polyisobutylene (PIB), polystyrene (PS), polystyrene-co-butadiene (PSB)] was studied using the quartz crystal microbalance (QCM). QCM measurements revealed a modest increase in sensitivity towards toluene for PB and PIB membranes at concentrations above 90 ppm after aging in water for 4 days. In contrast, the sensitivity of PS and PSB coated QCM sensors depended significantly on the toluene concentration and increased considerably at concentrations above 90 ppm after aging in water for 4 days. Attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) showed that there is a change in the sorption mechanism at higher toluene levels for PS and PSB. Positron annihilation lifetime spectroscopy (PALS) studies were performed to investigate the free volume properties of all polymers and to monitor any changes in the free volume size and distribution due to water and toluene exposure. The PALS did not detect any considerable variation in the free volume properties of the polymer films as a function of solution composition and soaking time, implying that viscoelastic and/or interfacial processes (i.e. surface area changes) are probably responsible for variations in the QCM sensitivity at high hydrocarbon concentrations. The results suggest that polymer membrane conditioning in water is an issue that needs to be considered when performing QCM measurements in the aqueous phase. In addition, the study shows that the hydrocarbon response is concentration dependant for polymers with a high glass transition temperature, and this feature is often neglected when comparing sensor sensitivity in the literature.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.aca.2011.07.015

Additional details

Identifiers

DOI
10.1016/j.aca.2011.07.015;
PII
S0003-2670(11)00956-1;

Publishing Information

Journal Title
Analytica Chimica Acta
Journal Volume
703
Journal Issue
1
Journal Page Range
p. 70-79
ISSN
0003-2670
CODEN
ACACAM

Optional Information

Copyright
Copyright (c) 2011 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.